Technical Specifications
Warranty Information
All the products supplied by Evelta are genuine and original. We offer 14 days replacement warranty in case of manufacturing defects. For more details, please visit our cancellation and returns page.
All the products supplied by Evelta are genuine and original. We offer 14 days replacement warranty in case of manufacturing defects. For more details, please visit our cancellation and returns page.
| load type | Typical applications | Rating | Max DC load capacity
|
| AC1 | Non-inductive or slightly inductive loads |
16A @ 250V AC | |
| AC15 | Control of electromagnetic load (>72VA) |
3A @ 120V AC 1.5A @ 240V AC |
|
| AC3 | Control of the motor | 750W | |
| DC1 | Non-inductive or slightly inductive loads |
16A @ 24V DC | |
| DC13 | Control of electromagnetic loads |
0.22A @ 120V DC 0.1A @ 250V DC |
Example Code Download Link:
Java - a command-line application for controlling the module
Perl - Simple example of setting an output active/inactive by TCP
PHP script - Simple example of setting an output active/inactive by TCP
Python V2 - command line application for controlling the module
Python V3 - command-line application for controlling the module
Visual Basic - source code for a simple program, which includes a UDP scan to determine any boards connected to the local network
Visual C# - source code for a simple program, includes a UDP scan to determine any boards connected to the local network
Q: What is the maximum current rating per channel for this relay module?
A: Each channel of this relay module can handle a maximum current of 16A.
Q: Can I control this relay module remotely over a network?
A: Yes, this relay module is designed for remote control. It features an RJ45 Ethernet port for connecting to a network, allowing you to control the relays via software or network commands.
Q: What are the different communication protocols supported by this module?
A: This relay module supports multiple communication protocols, including Modbus TCP/IP and HTTP. This provides flexibility in integrating the module with your existing systems.
Q: Is this relay module suitable for industrial applications?
A: Yes, this relay module is designed for industrial environments. It has a DIN rail mountable design and can operate within a wide temperature range of -25°C to +70°C.
Q: What is the purpose of the dry contact input on this module?
A: The dry contact input can be used to trigger events or actions on the relay module. For example, you could connect a sensor to the dry contact input to automatically activate or deactivate a relay when the sensor is triggered.