Technical Specifications

Brand:
SPEC Sensors
Detection Limit:
0.5 ppm
Measurement Range:
0 to 1,000 ppm
Response Time – T(90):
< 30 seconds (15 seconds typical)
Resolution:
< 100 ppb (instrumentation dependent)
Sensitivity:
4.75 +/- 2.75 nA/ppm
Repeatability:
< 2 % of reading
Overload:
Passes EN50291-1 Sec. 5.3.6 5,000 ppm overload
Operating Humidity Range – non-condensing:
15 to 95% recommended continuous 0 to >95% RH - intermittent
Operating Temperature Range:
-30 to 55 C (-20 to 40 C continuous recommended)
Power Consumption:
10 to 50 uW (circuit & ambient CO dependent)
Expected Operating Life:
> 5 years (10 years @ 23 +/- 3 °C; 40 +/- 10% RH)
Operating Bias:
0 to 5 mV
Target Gas:
Carbon Monoxide CO

Warranty Information

All the products supplied by Evelta are genuine and original. We offer 14 days replacement warranty in case of manufacturing defects. For more details, please visit our cancellation and returns page.

Description

SPEC Sensors’ Screen Printed ElectroChemical sensor technology (SPEC Sensor) revolutionizes the current state of the art, enabling new applications in consumer and industrial safety monitoring. SPEC’s printed sensors offer the performance of the best quality electrochemical sensors at a fraction of the price. SPEC’s printed sensors are also ultra-thin, offering easy integration into wireless, portable, and networked solutions. These sensors are ideal for health, environmental, industrial and residential monitoring, because of their high performance, low cost and small size.

 

Resources

3SP_CO_1000 C Package 110-109

UL2034 Certificate of Compliance for CO

Carbon Monoxide Risks at Low Levels

SPEC Sensor Operation Overview

SPEC AN-103 Power-On Stabilization

SPEC AN-104 Environmental Effects

SPEC AN-105 Selectivity and Cross-Sensitivity

SPEC AN-106 Gas Sampling and Material Considerations

SPEC AN-107 Characterization and Calibration

UL ETL Part Number Package Number Reference